- New product
Description
Explosion-proof hydraulic valves are designed according to extreme criteria, which are tested at the factory before each shipment. These explosion-proof valves withstand explosive atmospheres of dust and gases. The design for the explosive atmosphere valve is designed to withstand mechanical damage. Exd I - this protection for explosive valves in mines is resistant to methane, coal dust, hydrogen sulphide and carbon dioxide. Exd II BT4 - this protection for explosive valves is intended for use in explosive gas zones (class II A, II B, temperature class T4) Same as in steam zone 1 or steam zone 2.Exd II CT4 - Can be used in places with explosive gases (II A, class C, temperature class T4)
Data sheet
- Reference
- 914
- Mass
- 3.0 kg
- Designation
- GDBYZ-02-5-D24-B
- Connection
- NG06 (CETOP 03)
- Maximum working pressure (bar)
- 315.0 bar
- Pressure range
- 0-50 bar
- Tension
- 24 V DC
- Security
- IP65
- Maximum flow
- 2.0 l/min